Sales: 0161 925 7650

Technical Training

PANASONIC TECHNICAL TRAINING

NS700 - 1 day top up course £95 + vat per delegate
Pre requisites: Engineers must have knowledge of programming TDA/NCP/TDE systems. If the engineer only has TD or no knowledge then they will need to attend the 3 day course.
Manchester Dates (Course Instructor Paul Gorrigan)
TBC
Bracknell Dates (Course Instructor Paul Gorrigan)
TBC

Course Agenda:

  • Installation & configuration
  • New hardware
  • Wiring of high density cards
  • KX-NS720 Expansion cabinets
  • KX-NS0154 IP cell station
  • SVM/UM and DISA explanation
  • Programming tool overview
  • Version 4 features
  • KX-NS1000/700 differences

NS700/NS1000 Technical Training – 3 day course
£295 + vat per delegate - Nimans ONLY location
£350 + vat per delegate - Bracknell location
Pre requisites:For engineers who have no knowledge or TD knowledge only.
Manchester Dates (Course Instructor Paul Gorrigan)
TBC
Bracknell Dates (Course Instructor - Paul Gorrigan)
TBC

Course Agenda:
Day 1

  • Introduction to NS platform – History and brief on V1-4
  • Capacity
  • Hardware NS1000
  • Hardware NS700
  • Installation of Offline Programming Tool
  • Installation & Configuration NS1000
  • Installation & Configuration NS700
  • Wiring NS700 & High Density Cards
  • 1 - Easy Setup Wizard NS700
  • 1 - DHCP Server Setup
  • 2 - IP Handset Registration
  • 2 - User Profiles
  • Programming Tool Overview – Backup & Upload
  • 3 - Basic Programming
  • 4 - Extension Programming
  • 5 - Licensing
  • 6 - Trunk Programming (SIP Loopback)
  • SIP Loopback Setup: ISDN Trunk setup and trunk setup options, Analogue line routing, DDI Routing, CLI Routing
  • 7 - Toll Restriction: Setup TRS on Extension 202 and 203 to restrict dialling 09 numbers, but allowed to dial 0980 numbers. Remember 141 and 00 in restriction tables. Discuss Speed Dial TRS and it’s implications.

Day 2

  • 8 - ESVM
    Setup ESVM Voicemail on Extension 201 & 202 with intercept on Busy NA for 10 Seconds. Record greeting messages and demonstrate the function on single line display vs multiline display.
  • 8 - Group ESVM
    Setup Group VM extension 300, use manager to record greetings and then setup Flexible button to retrieve VM message. Setup ICD Group with overflow to VM and demonstrate operation.
  • 9 - DISA AA
    Setup DDI to call DISA 501, Record message from manager extension, if nothing is pressed route to ICD Group 601 or dial extension number if known. Reduce down DISA Timers.
  • 9 - DISA Multilevel AA
    DDI to route calls to DISA 502, Options to route to ICD Group 601 or to route to another level to give more options, all options route to 601, to demonstrate multilevel.
  • 10 - ICD Groups – Basic
    Setup group names and include the same extensions in each group, showing that the group name will show up on the extensions. All ring groups.
  • 10 - ICD Groups – Delayed, ACD, UCD, Priority
    Demonstrate the difference between all group types and setup Extension step on timers.
  • 10 - ICD Groups – Login/Logout, Wrap-up
    Login Logout buttons on the extensions, also setup extension wrap-up timer of 30 seconds and demonstrate the use of the wrap-up button.
  • 10 - Supervisor/Group monitor
    Group Monitor button on a 6 line display handset and show the features.
  • 10 - ACD Stats
    Use PPT to setup ACD stats user. Show the options of reporting.
  • 11 - Call Queuing
  • 11 - Position in Queue
  • 12 – User Groups
  • 12 - Paging Groups
  • 12 - Pickup Groups
  • 12 - Tennant Groups
  • 12 – Call Block
  • IP Softphone

Day 3

  • SIP Trunks – Use Gamma Example
  • SIP Extension – Setup Media 5 on WLAN
  • DSP Resource Calculation
  • Media Relay Gateway – Theory PPT
  • DECT
  • UM Basic Mailbox Setup
  • UM Group Mailbox
  • UM Custom Service
  • UM Voicemail to Email
  • UM Two way Record/Record Control
  • Software Upgrade
  • OneLook Networking

 

For availability, booking, accommodation (Manchester) and further course information CALL  0161 925 1900 or email: PANASONIC@NIMANS.NET

To book please provide a purchase order number and delegates name/s and email address. On receipt of your PO confirmation will be sent to you. Refreshments and a buffet lunch will be provided; we can cater for all dietary requirements.

We advise you not to book any non-cancellable hotel accommodation well in advance of any course dates just in case the course has to be cancelled at relatively short notice due to unforeseen circumstances.

Cancellation Policy: Delegate(s) must notify Nimans Ltd no later than 7 working days before the course start date, otherwise you will incur a £50.00 cancellation fee per delegate on top of the course cost.

Location details:
Manchester:
Nimans HQ, Agecroft Road, Manchester, M27 8SB
Bracknell: Panasonic HQ, Willoughby Road, Bracknell, Berkshire, RG12 8FP

We reserve the right to cancel any scheduled courses at short notice should the delegate numbers not reach the minimum quantity criteria to make the course financially viable.


eCommerce by: Cohesion Digital